QuietJoint® |
|||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
|
|
|||||||||||||||||||||||||||||
|
QuietJoint-SHH is coated on two faces and is ideal for gaps between opaque or solid partitions or walls. The coating can be the same color on both faces or different on each face to coordinate with wall coverings. QuietJoint-SHG is coated on a third face and is typically used to fill gaps between the glass of curtainwall or windows on one side and solid substrates on the other. The third coating aesthetically covers the foam core so that the foam is not visible through the glass. The coating can be the same color on all three faces or different on each face to coordinate with wall coverings. (Note: color transitions between different faces may blur). ABOVE: QuietJoint SHG installed between window glass and end of wall partition. The third silicone side faces the glass. The silicone color of this sample is Dow 790 Sandstone and was chosen deliberately to contrast with the surrounding colors. A "Bronze" color choice would allow the QuietJoint to coordinate completely with the bronze mullion. The image above was shot with a short piece of QuietJoint for illustration purposes. In reality the 10-LF supply lengths would allow installation in the entire run without any joins. In close-up the installation looks like this: Color-switching can be used with QuietJoint to coordinate with bands of color in a wall's color scheme. In the example above, the"Bronze" silicone was chosen to best blend with the metal window mullion. 26 sealant face colors are available |
For vertical and
horizontal-plane joint-gaps from 1/2"
(12mm)
to 6"
(150mm).
|
||||||||||||||||||||||||||||
|
- 2"
(50mm)
standard depth - one side of wall only |
- 2" (50mm) standard depth - both sides of wall |
||
![]() |
STC 53
OITC 38 *when tested in a STC 56 (OITC 38) wall |
![]() |
STC 72 OITC 60 *when tested in a STC 72 (OITC 61) wall |
Independent laboratory tested to ASTM E90-09, "Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements".
Click here for the independent laboratory test report (.pdf)
Insulation Value--Control HVAC balance and energy loss between rooms
The R-value of QuietJoint foam
is R-2.848/inch of depth.
Depending on the joint size and related depth, the R-value of the material
will be:
| Material |
R-Value (installed one side of joint) |
R-Value (installed both sides of joint) |
| 1/2" to
4.75" with 2" depth (12mm to 120mm with 50mm depth) |
5.696 | 11.39+* |
| 5"
to 6" wide with 3-inch depth (125mm to 150mm with 75mm depth) |
8.544 | 17.088+* |
*Assumes installation from both sides of the wall thereby doubling the R-value. The inclusion of an air gap between the two pieces of QuietJoint will add additional insulation, effectively more than doubling the R-value.
Independent laboratory tested to ASTM C518-04 "Standard Test Method for Steady-State Thermal Transmission Properties by Means of the Heat Flow Meter Apparatus".
Click here for the independent laboratory test report (.pdf)
Material Sizing:
QuietJoint is available in 1/4-inch (6mm) increments for field-measured joint openings from 1/2" (12mm) up to 6-inches (150mm) with depths according to the following chart:
| Joint Sizes | Depth of Seal | Length |
|
1/2 - 4.75" (12 - 120mm) |
2"
(50mm) |
10-ft (3 meters) |
|
5 - 6" (125 - 150mm) |
3"
(75mm) |
10-ft (3 meters) |
QuietJoint-SHH is coated on two faces and is ideal for gaps between opaque or solid partitions or walls. The coating can be the same color on both faces or different on each face to coordinate with wall coverings.
QuietJoint-SHG is coated on a third face and is typically used to fill gaps between the glass of curtainwall or windows on one side and solid substrates on the other. The third coating aesthetically covers the foam core so that the foam is not visible through the glass. The coating can be the same color on all three faces or different on each face to coordinate with wall coverings. (Note: color transitions between different faces may blur).
Limitations:
Over compressing QuietJoint can result in backpressure that could exceed the ability of certain substrates to resist this pressure. User is assumed to have tested all applications to ensure suitability for use.
Not intended for use in moving joints. Not trafficable. For watertight, moving structural joint gaps see EMSEAL Product and Application Index.
Expansion joints and precompressed joint sealants by EMSEAL
1-800-526-8365 -- 508-836-0280 --
techinfo@emseal.com
-- Fax: 508-836-0281
EMSEAL JOINT SYSTEMS LTD. 25 Bridle Lane, Westborough, MA 01581
EMSEAL LLC. 120 Carrier Drive, Toronto, ON M9W 5R1
Last Modified: February 09, 2012
Copyright © 1998-2012 by EMSEAL
Joint Systems, Ltd. All rights reserved.
This document may not be reproduced in whole or in part without permission.