TWINSERT Series--Wide Floor Expansion Joints


More on Floor Joints:

How to Select Floor Joints

Healthcare Point Loads

Reference List

 Products

CAD


TWINSERT is a series of highly configurable interior expansion joints for bridging wide joint gaps and/or for blending the joint system with adjacent flooring materials.

Each TWINSERT model is created by bridging any two of EMSEAL's standard interior joint systems. 

The bridging element is usually made of custom-configured aluminum. 

The bridging element can become part of the finished, visible and trafficked surface of the joint...

or,

...like a "pan" joint, it can be recessed to support any floor material--tile, terrazzo, stone, etc.-- being used elsewhere on the floor. 

In contrast to "pan" joints, however, the bridging element can be configured to handle heavy loads that often lead to cracking of infill materials in lighter-duty systems (see TWINSERT in action at Washington DC Convention Center).


Example 1 of 2:  FS 110 TWINSERT with Aluminum Traffc Plate

In this example, twin FS 110/45, heavy-duty, aircraft-aluminum joints have been connected with a 1/2" (12mm) aluminum bridging plate.

The width of the plate has been custom made to allow the bridging of an 8-inch wide expansion joint gap.

The thickness of the plate was calculated to handle forklift and vehicle loads required by the client--the Washington DC Convention Center (click here for a project profile and to see the installed TWINSERT).

In this particular application, the TWINSERT was installed into a recess (blockout) on each side of the joint gap and installed proud of the surrounding concrete by the thickness of the adjacent carpet. As a result, the TWINSERT system sits flush with the finished walking and traffic surface.
 


Example 2 of 2:  FP 70/30 TWINSERT with Recessed Plate for Tile

In this example, twin FP 70/30, medium-duty, aluminum/elastomeric insert joints have been connected with a 1/4" (6mm) aluminum bridging plate that is recessed from the finished surface of the joint to receive field-installed tile to match the floor.

The joint gap in this application is only 3-inches but movement due to uncontrolled airspace below the lobby floor results in movement in excess of that which could be handled in numerous previous attempts using other manufacturers standard floor products for 3-inch joints. 

By using twin FP 70's the movement capability is doubled.  By spacing them out so that tile can be installed between them allowed coordination with black accent tiling patterns.


Joint Sizing:
Theoretically, TWINSERT can be configured to handle ANY joint size.  As long as a bridging material suitable to the loads expected can be secured to the selected standard joint system, this bridging material can be made to span joints as large as 24-inches.
 

Movement Capability:
The movement capability of any TWINSERT configuration is equal to 2-times that of the standard model from which it is configured.
 

Load Capacity:
TWINSERT can be configured to match the loading capacity of the standard EMSEAL interior joint system chosen as the flanking systems.  This allows configuration of TWINSERT for Standard, Medium or Heavy duty use including:
  • Fork Lifts
  • Trucks
  • Scissor Lifts
  • Gurneys
  • Coin Carts
  • Luggage Carts
  • Hand Trucks
  • Pedestrians
  • Mobile Medical Equipment
  • Emergency Vehicles
  • Vendor Carts
  • Maintenance Equipment

For assistance in calculating wheel loads of expected vehicles--Consult EMSEAL

Floor-to-Wall Versions:
Floor-to-Wall versions of TWINSERT can be configured in accordance with the floor-to-wall options available with the standard joint system selected as the flanking system--consult the product page for the specific system.

Leg-Height Options:
As with loading capacity and floor-to-wall options, leg heights are driven from those available in the standard joint system selected as the flanking system.

This option also allows for using DIFFERENT leg heights on either side of the bridging element.  You might choose this option if there is a floor height differential across the joint.
 


Need Help Configuring TWINSERT to your application?

Contact EMSEAL: techinfo@emseal.com; Toll Free: 1-800-526-8365 or 508-836-0280
 


--"Interior-Floor Expansion Joint Checklist"--

 
   

(Need help with Floor Expansion Joints? Fax or Email Us This Checklist)


Meet online now:

 

Expansion joints and precompressed joint sealants by EMSEAL

1-800-526-8365 -- 508-836-0280 --  techinfo@emseal.com -- Fax: 508-836-0281

EMSEAL JOINT SYSTEMS LTD. 25 Bridle Lane, Westborough, MA 01581
EMSEAL LLC. 120 Carrier Drive, Toronto, ON M9W 5R1

Last Modified: February 09, 2012



Copyright © 1998-2012 by EMSEAL Joint Systems, Ltd. All rights reserved.
This document may not be reproduced in whole or in part without permission.